- 天然气压缩机用10KV 1000KW高压电机固态软启动柜奥东电气ADGR
详细信息
品牌:奥东电气 加工定制:是 型号:ADGR 用途:减压起动 额定电流:500 A 额定电压:10000 V 适用电机:鼠笼型电机 适用领域:石油化工;电力工业;冶金钢铁;城市建设 厂家直销天然气压缩机用10KV 1000KW高压电机固态软启动柜10KV,500KW,800KW,1200KW,1600KW,2000KW备有现货直接销售,高压固态软启动柜即晶闸管起动柜,在天然气压缩机起动过程中有效降低起动电流的作用,使空压机能够平滑平稳的起动,以下是针对10KV 1000KW高压固态软启动柜的相关参数做详细介绍;
基本参数Basic parameters(技术咨询热线: 乔经理)
负载种类
Type of load
三相高压鼠笼式异步电机、同步电机
Three-phase squirrel cageasynchronous andsynchronous motors
交流电压
AC voltage
3000---10000VAC
工作频率
Service frequency
50HZ/60HZ±2HZ
相序
Phase sequence
CMV允许在任何相序下工作(可通过参数设定)
CMV is allowed to work with any phase sequence (through setting parameter)
主回路组成
Composition of major loop
(12SCRS、18SCRS、30SCRS视型号而定)
(12SCRS、18SCRS、30SCRS depend on model)
旁路接触器
Bypass contactor
具有直接起动容量的接触器
Contactor with direct starting capacity
控制电源
Control power
AC220V±15%
瞬时过电压保护
Transient voltage overload protection
dv/dt吸收网络
dv/dt snubber network
起动频次
Start frequency
1—6次(每小时)
1-6 times per hour
环境条件
Ambient condition
环境温度:-20°C -+50°C
Ambient temperature: -20°C -+50°C
相对湿度:5%----95%无凝露
Relative humidity: 5%----95% no condensation
海拔小于1500米(大于1500米需降容使用)
Altitude less than 1500m (derating when altitude is more than 1500m)
保护功能Protective functions
缺相保护
Open-phase protection
在起动或运行过程中,断开主电源的任意相
Cut off any phase of primary power supply in the course of starting or operation.
运行过流保护
Over-current protection in operation
运行过流保护设定:20~500%Ie
Operational Over-current protection setting: 20~500%Ie
相电流不平衡保护
Unbalanced phase current protection
相电流不平衡保护:0~100%
Unbalanced phase current protection: 0~100%
过载保护
Overload protection
过载保护级别:10A、10、15、20、25、30
Overload protection grade: 10A、10、15、20、25、30
欠载保护
Underload protection
欠载保护级别:0~99%
欠载保护动作时间:0~250S
Underload protection grade: 0~99%
Action time of underload protection: 0~250S
起动超时
Start timeout
起动时间限制:0~120S
Start time limit: 0~120S
过压保护
Over-voltage protection
主电源电压高于额定值的120%时,过压保护
When voltage of primary power supply is 120% higher than rated value, over-voltage protection is enabled.
欠压保护
Under-voltage protection
主电源电压低于额定值的70%时,欠压保护
When voltage of primary power supply is 70% lower than rated value, under-voltage protection is enabled.
相序保护
Phase protection
允许在任何相序下工作(可通过参数设定)
Allow to work with any phase sequence (through setting parameter)
接地保护
Ground protection
接地电流大于设定值时保护
Protection available when grounding current is higher than set value
通讯说明Description of communication
通讯协议
Protocol
Modbus RTU
通讯接口
Communication interface
RS485
网络连接
Network connection
每台CMV可与32台CMV设备连网通讯
Each CMV can communicate with 32 CMV equipments in network.
功能
Function
通过通讯接口可以观察运行状态、编程
Operation state and programming can be observed through communication interface.
操作界面Operating interface
LCD显示
LCD display
LCD(液晶)显示/触摸屏显示
LCD display/touch screen display
语言
Language
中、英文
Chinese and English
键盘
Keyboard
6个触摸式薄膜按键
6 touch membrane keyboard
仪表显示Meter display
主电源电压
Voltage of primary power supply
显示三相主电源电压
Display voltage of three-phase primary power supply
三相电流
Three-phase current
显示三相主回路电流
Display current of three-phase major loop
数据记录Data record
故障记录
Fault history
记录*近15次故障信息
Record recent 15 faults information
起动次数记录
History of number of starts
记录本装置的起动次数
Record number of starts of this soft starter
奥东电气生产的ADGR系列高压固态软起动装置,主要适用于鼠笼式异步、同步电动机的起动和停止的控制与保护。它采用高质量串并联用晶闸管,无级控制输出电压、使电动机平稳地起动和停止。它具有过载、缺相、运行过流等故障保护功能,使用它能有效地避免因电动机起动电流过大给电网带来的有害冲击、能在有限的电网容量下正常使用大功率电机并延长其使用寿命。
高压固态软起动柜检测过程:
ADGR系列高压固态软起动装置特点:
1、采用高压功率晶闸管,组件式结构、模块化设计,便于安装维护。
2、具有多重过电压吸收、保护技术。
3、具备直接起动功能。在维修过程中即使发生故障,电机也可以采用直接起动方式工作,*大限度地延长运行时间。
4、采用32位ARM核微控制器执行中心控制,控制实时高效、显示直观、可靠性高、稳定性好。
5、采用高抗干扰性的数字式触发器与光纤隔离技术、使得装置的高、低压做到可靠的隔离。
6、中/英文液晶显示系统,操作界面人性化。
7、具有RS-485通讯接口,可与上位机或集中控制中心进行通信,Modbus/Profibus标准协议可选.
奥东电气厂家直销天然气压缩机用10KV 1000KW高压电机固态软启动柜,还有其它规格,其它类型的软起动,如高压笼型水阻软起动,绕线软起动,高压磁控软起动柜,高压电抗软起动柜等,都是与压缩机配套的软起动,欢迎您来考察奥东电气高压固态软启动柜。
-
-
公司相册
-
配套设备(开关柜励磁柜)
31张图片 -
消防巡检柜
18张图片 -
无功补偿类(补偿柜,SVG)
98张图片 -
高压变频器
72张图片 -
笼型水阻柜
30张图片 -
高压固态软起动类(固态,磁控,电抗)
108张图片 -
生产车间试验平台
22张图片
-